FIN EC software

Online Help

Tree
Settings
Program:
Language:

Head

The column head that increased the slab resistance in punching can be specified in this part.

Head

The part "Head" contains the choice of head type and dimensions. Following types are available:

No head

  • The column does not have any head

Column-shaped head

  • The shape of the head respects the shape of column cross-section. The dimensions are given only by the distance from the column edge to head edge x.

Rectangular head

  • The head has rectangular shape. The dimensions are given by the orthogonal distances from the outer points of column cross-section.

Haunch

This part contains the geometry of head section. Following options may be chosen:

Step

  • The bottom surface of the head is horizontal, the head is ended with vertical edge.

Oblique

  • The bottom surface of the head is inclined.

User defined

  • Combination of previous options. This type contains horizontal, inclined and vertical parts. Both the length of horizontal part and the height of the vertical part may be defined as 0.

Frame "Head"

Try FIN EC software yourself. Download Free Demoversion.